Environment

ASTM F138 PDF

ASTM Fa. Standard Specification for Wrought 18ChromiumNickel Molybdenum Stainless Steel Bar and Wire for Surgical Implants. Find the most up-to-date version of ASTM F at Engineering Mechanical values listed above are typical for uniaxial tension. Upon request, we can also deliver this material with other properties. L (ASTM F), Ti.

Author: Kigakazahn Nalabar
Country: Togo
Language: English (Spanish)
Genre: Software
Published (Last): 21 May 2016
Pages: 287
PDF File Size: 5.6 Mb
ePub File Size: 11.34 Mb
ISBN: 714-1-49094-736-5
Downloads: 97487
Price: Free* [*Free Regsitration Required]
Uploader: Vugal

If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. BrinellB Hardness, max, HB The heat analysis shall conform to the requirements as to chemical composition specified and c138 material shall contain no delta ferrite, chi, or sigma phases when it is examined by metallography.

ASTM F植入不锈钢棒材和线材_百度文库

While most manufacturers quickly turn to material costs as a primary means of lowering their price, these short-term accommodations are not always sustainable. Atsm Typically supplied as hot-rolled bar for forging applications.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every? Acceptance criteria shall be agreed to between pruchaser and supplier. Different tests shall be performed in order to determine the following mechanical ast of the wire and bar: Materials and Manufacture 5. The technical data provided is for information only and not for design purposes.

  KORIDOR PEMBANGUNAN SABAH PDF

LS / LVM Surgical Stainless Steel Bar – ASTM F

Please contact us for more details. Analysis for elements not listed in Table 3 is not required to certify compliance with this speci? F Specification for Wrought f38 Published information has shown no adverse effect for compositions containing up to 1.

Billet shall also be ultrasonically tested prior to being hot rolled and should be free of internal defects.

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Due to the well characterized level of local biological asrm established by this material, it has been used as a control material in Practice F The chemistry modifications are designed to maximize the corrosion resistance of this alloy and provide a ferrite free microstructure.

316LS / 316LVM Surgical Stainless Steel Bar – ASTM F138

Advanced ladle metallurgy allows for fine adjustments of the composition, amount, size, shape and distribution of the aatm inclusions normally occurring within standard stainless steel.

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.

Mm Ksi MPa Up to 0. The secondary premium melting step imparts improved cleanliness. This specification covers the requirements for wrought 18chromiumnickel The alloy is nonmagnetic even after severe cold forming operations. Find out more by contacting us at On the other hand, types of finish available for fine wire products are cold-drawn, ground, and ground and polished.

  JEREMIAH WAS A BULLFROG PIANO PDF

Current edition approved June 10, Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. General Requirements for Delivery 3.

The level of mechanical properties for material in conditions other than those included in Table 1 and Table 2, shall be speci? However, long term clinical experience has shown an acceptable level of biological response can be expected, if the material is used in appropriate applications.

Alternatively, a gage length corresponding to ISO may be used when agreed upon between supplier and purchaser. Types of finish available for bar and wire products are cold-drawn, pickled, ground, and ground and polished.

A number in parentheses indicates the year of last reapproval. Originally approved in Recommended crosshead speed for cold-drawn? Under minimum limit not applicable for elements where only a minimum percentage is indicated.