Education

ASHRAE STANDARD 55-2010 PDF

ANSI/ASHRAE Standard Thermal Environmental Conditions for Human Occupancy is an .. ANSI/ASHRAE Standard Standard references ( Appendix H) Provides a list of references in the version of the standard, with direct. ANSI/ASHRAE Standard (Supersedes ANSI/ASHRAE Standard ). Includes ANSI/ASHRAE addenda listed in Appendix |. o) ASHRAE. ANSI/ASHRAE Standard 3. It is intended that all of the criteria in this standard be applied together since comfort in the indoor environment is.

Author: Vudogis Gardalmaran
Country: Bhutan
Language: English (Spanish)
Genre: Photos
Published (Last): 8 December 2014
Pages: 221
PDF File Size: 14.99 Mb
ePub File Size: 5.66 Mb
ISBN: 732-9-79186-756-5
Downloads: 69574
Price: Free* [*Free Regsitration Required]
Uploader: Nilar

In order to achieve acceptable results, the standard also suggests the minimum equipment accuracy based the current industry standard. Except sedentary activities, metabolic rate for all other activities is likely to have range of variation. Prevailing mean outdoor temperature. One has to keep in mind that the results from point-in-time surveys are only effective during the time when the surveys were solicited.

After the body of the standard there are 11 informative appendices. Metabolic rate is the rate of transformation of chemical energy into heat and mechanical work by metabolic activities of an individual, per unit of skin surface are expressed in units of met equal to If that number is between 20 and 45, the minimum number of responses is To evaluate the thermal comfort over a period of time in a mechanically conditioned space, the exceedance hours are the sum of all the hours when the absolute value of PMV is greater than 0.

Retrieved from ” https: It also added a general satisfaction survey to section 7 intended to evaluate general thermal comfort in an occupied space, bringing the standard in line with current survey-based post-occupancy evaluation POE practices.

Standard 55 specifies conditions for acceptable thermal environments and is intended for use in design, operation, and commissioning of buildings and other occupied spaces.

You can also still use the operative temperature button, yet each point will have the same MRT. In the standard was updated with more extensive information on measurement protocols and an expanded definitions section.

Standard 55 – Thermal Environmental Conditions for Human Occupancy

Generally, the evaluation of comfort in existing buildings can be performed from two perspectives: The standard reminds the users that they should use their own judgment to match the activities being considered to the comparable activities in the table.

  GOLI RUCAK PDF

This page was last asnrae on 12 Septemberat When the duration of an activity is equal or less than one hour, one can use a time-weighted metabolic rate. Looking for previous revisions of this standard? Compliance is achieved if the conditions provide thermal neutrality, measured as falling between This table can be used together with the previous one, so that one can add or subtract the clothing ensemble from the clo value of each garment.

The systems must be able to maintain these conditions within the expected range of indoor and outdoor operating conditions. The methodology is based on the SET Standard Effective Temperature model, which provides a way to assign an effective temperature at a standard metabolic rate, and clothing insulation values to compare thermal sensations experienced at a range of thermal conditions.

To cite this webpage: We recommend using Chrome, Firefox, or Safari. In the body of the standard was rewritten in mandatory language, with informative language moved from the body of the standard to informative appendices. Psychrometric chart air temperature Psychrometric chart ashrqe temperature Temperature — Relative Humidity chart Operative Temperature — Velocity chart. For this model the standard provides a graph of acceptable indoor temperature limits at prevailing mean outdoor temperatures a mean of the daily mean outdoor temperatures of the previous 7—30 days.

To demonstrate compliance stanfard following must be documented, where applicable. No local air speed control With local air speed control.

Internet Explorer is not fully supported. When the number is under 20, at least 16 must reply for asgrae survey to make the survey representative. If there are multiple such locations, the measurement can be performed at stanxard representative location. It was revised ashrqe,and There is a figure in the section five of the standard which predicts the representative clothing insulation of the occupants as a function of the average outdoor air temperature at Views Read Edit View history.

There is a variety of means to determine the insulation provided by clothing. The section sets provisions for increasing the upper air temperature limit at elevated air speeds above 0. In this psychrometric chart the abscissa is the dry-bulb temperature, and the mean radiant temperature MRT is fixed, controlled by the inputbox.

Clothing insulation is the resistance to sensible heat transfer provided by a clothing ensemble expressed in units of clo, which ashraee a unit to quantify the insulation provided by garments and clothing ensembles.

  GNOBLAR HORDE PDF

For occupant-controlled naturally conditioned spaces, the measured results shall be check with the comfort zone established by adaptive model. When extracting environmental data from the Building Administration System, one should evaluate the location, height, and time step of the sensors based on the previous suggestion.

Radiant temperature asymmetry between ceiling and floor, and air and walls must be limited to reduce discomfort. There should be at least seven points on the scale ending with “very acceptable” and “very unacceptable. All informative background information has been moved to informative appendices. And this equation is only valid when the metabolic rate is between 1.

Given the widespread and easy accessibility of computing power and third-party implementations of the analytical method, it is expected that more users will favor the comprehensive analytical methods over the graphical method. These values are valid for an average adult with surface skin area of 1.

Considering that a sleeping person or one in reclining standzrd will be provided with sufficient insulation with the bedding material, and he or she is also free to adjust, it is impossible to determine the clothing insulation effect for these occupants unless they are immobile. Heating, ventilating, and air conditioning Building engineering Heat transfer Architecture Architecture occupations.

Comfort zone refers to the combinations of air temperature, mean radiant temperature trand humidity that are predicted to be an acceptable thermal environment ashraw particular values of air speed, metabolic rate, and clothing insulation I cl [1].

The measured results should be evaluated against the adjusted comfort zone for the specific building.

Standard 55 – Thermal Environmental Conditions for Human Occupancy

For satisfaction surveys, the thermal satisfaction scale shall end with choices: From Wikipedia, the free encyclopedia.

If these requirements are met and the environmental conditions inside the building fall within the indicated ranges, then compliance is achieved. Accurate data from the measurement using thermal manikins is acceptable.

No heating system is in operation; b Metabolic rates ranging from 1.