CS Installation Instructions This manual contains installation details for the CS control panels. It provides the basic programming and. CS Installation InstructionsThis manual contains installation details for the CS control panels. It provides the basic programming and inst. You can examine Aritech CS Manuals and User Guides in PDF. View online or download 1 Manuals for Aritech CS Besides, it’s possible to examine.

Author: Vudokasa Voodoolmaran
Country: Netherlands
Language: English (Spanish)
Genre: Love
Published (Last): 8 March 2009
Pages: 119
PDF File Size: 1.74 Mb
ePub File Size: 15.84 Mb
ISBN: 524-1-41094-714-9
Downloads: 58870
Price: Free* [*Free Regsitration Required]
Uploader: Fenrijinn

Aritech CS350 Installation Instructions Manual

Replace the cover of the RKP and ensure that the tamper switch in the panel is closed. The following three keystroke sequences are possible: See also Peridiax programming on p.

If set to OFF then this output resets when the system is disarmed. See the Programming Map and Programming Functions for operational details. Trouble Indicates a system error: Install Remotes Output Type5. Aritech Corp assumes no responsibility for any errors which may appear in Documents. Enter manuao Keypad 1 the default engineer’s code [0][1][2][7][8]. Connection details for CS The Outputs are fairly straight forward.

The quick codes are as follows: Immediately after you enter the engineer code, keyin one of the digit sequences as indicated in the Short Code List. The load of the bells is greater than the fuse rating, inserting a higher value fuse may damage the panel. Check that the battery fuse is not blown. Tamper Input is 24Hrs operational. Leave this 01 In 0x.

  BOAL TEATRO DEL OPRIMIDO PDF

Remember to comment, Documents. Us unset of system. Before installing the remote keypad RKP at it’s designated position, it may be connected at the control panel, to enable the engineer to commission the system. The pulse count ismonitored after the first triggering in a window of 30s with 1s intervals. Clear when closed Open zones are omitted till they close again. Exterior Bell Follows the exterior bell alarm time. Confirm changes to the description shown on the display after programming.

The RKP will display the cause of trouble.

Aritech CS350 Manuals

Ensure that the battery is fully charged and is aritexh enough to carry the load of the system. Remove all power from the panel. Control panel activates 1. Spread the load of the bells across the bell outputs or fit a relay and use the auxiliary power output to provide some of the current.

Silent or audible Personal Attack alarm is determined in function 6. Use Pulse keyswitches if more than one input is to be used as Key zone. Alarm zone does not activate system.

Aritech Cs Alarm Panel And Keypad For Sale in Blessington, Wicklow from cnugent

Output as shown is ‘High’. Bell Cutout nn Timers Menu Time hh: Never Rearm The same input will not re-trigger the sirens. The exterior bell and Perimeter bell output types will reset after this time alarm expired.

  EL HOMBRE DIOS MARIA VALTORTA PDF

Keyswitch fully arms system. This instruction manual Part No F Aritech Cs User Manual for Mmanual could be ideal for a company that wants to monitor this product is especially useful, Fs full set of system 3. When the existing engineer code is unknown, then the control panel must be returned to the factory for reprogramming.

Note that this also happens after returning to factory default.

Any combination raitech the above wiring methods is allowed with the restriction that the total cable length on each of the wiring loops either multidrop or star is restricted to m.

When a panel asks for [Call Engineer nn], were nn is a number, the user can’t arm his panel. Input s and code s must have the ‘In’ attribute to be able to force arming of the panel.

Check that the battery is connected correctly.